AM4 Series 35kV Medium Voltage Protection Relay

● A complete set of protection, related to the application;

● 4 current input, 4 voltage input, 12DI, 5DO;

● Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V;

● 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU;

● 1 RS232 for user update;

● 1 GPS for GPS timing;

● More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records;

● Powerful graphic programmable Logic.

 

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
product detail

General

AM series microcomputer protection measurement and control device set protection, measurement, control in one, suitable for 35kV and below the voltage level of the user terminal substation (station), can achieve the protection and measurement and control of the user substation. Application fields cover power, water conservancy, transportation, petroleum, chemical, coal, metallurgy and other industries.

Front Panel

LCD Display

Function

Installation

Dimension

 

Cut-out Dimension

Wiring

Typical Connection

PARAMETER
Rated Parameter Power Supply Power supply: AC/DC220V,Or AC/DC110V, or DC48V(Reference the wiring diagram)
Range: Power supply x (1±20%)
Maximum power consumption: ≤10W(DC)
Rated Voltage Rated Voltage: AC100V
Range: 1-120V
Accuracy: ±0.5%
Power Consumption: ≤0.5VA(Single phase)
Overload capacity: 1.2 times rated voltage for continous work; 2 times for 10 seconds
Rated Current Rated current: AC 5A/1A(See the device wiring diagram)
Range: 0.04In~15In
Power consumption: ≤0.5VA(Single phase)
Over capacity: 2 times rated current for continuous work; 40 times for 1 second
Frequency Rated frequency: 50Hz or 60 Hz
Range: 45~55Hz
Accuracy: ±0.1Hz
Digital Inut Rated Voltage: AC/DC220V,AC/DC110V, DC48V(Similar to power supply)
Voltage Range: Rated voltage x (1±20%)
Power Consumption: ≤1W(DC220V)(Single channel)
Digital Output Mechanical life: ≥10000 times
Switching capacity: ≥1000W, L/R=40ms
On current: continuous≥5A short time(200ms)≥30A
Interrupting capacity: ≥30W, L/R=40ms
Normal Working Conditions Ambient temperature: -10℃~+55℃
Device storage, transport allows the ambient temperature is -25℃~+70℃
Relative humidity: 5%~95%
Altitude: ≤4000m

FAQ

Q: How to set the CT and PT ratio of the protection device?

A: The protection device can set the CT and PT ratio through the fixed value menu. For example, the current transformer is 75/5 and the voltage transformer is 10/0.1, then the CT ratio is set to 15 and the PT ratio is set to 100.

Q: For AM4, if you want to place a circuit line protection and transformer protection, how to distinguish the model?

A: AM4 is suitable for circuit protection and transformer protection. No need to distinguish between models when placing orders

Q: When the voltage is three-phase three-wire system, does the current have to be connected with 2CT?

A: The voltage wiring mode and current wiring mode of the protection device can be set independently, and can be connected freely.

Q: How to confirm whether the anti-trip function is configured?

A: If the circuit breaker is equipped with anti-trip, the device does not must be equipped with anti-trip; if the circuit breaker does not have anti-trip, you need to configure the AM5-FT anti-trip module. (If DC48V is selected as the operating power supply, the anti-trip box is not optional, and the circuit breaker must be equipped with anti-trip function; if you choose AC anti-trip, please note that AC and DC general anti-tripping)

Q: How to purchase suitable protection devices?

A: Before ordering, it is recommended to consult related engineers, select the appropriate protection model, and then fill in the corresponding selection table, and place the order after confirmation by the engineers.

CONTACT US