Belt Wireless Temperature Sensor ATE200

● Wireless transmit, 470Mhz / 433Mhz;

● Wireless transmission distance, 150 meters;

● Fast sampling frequency, 25s;

● Battery-powered, more than 5 years;

● Widely temperature measuring range, -50℃~+125℃.

● Application: Switchgear, Busbar, Bus duct, Electric contact, Cable joint, Rain main unit and etc

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
product detail

General

ATE200 wireless temperature sensor has been developed in compliance with Specification for Wireless Temperature Measuring equipment, NB/T 42086-2016. It is suitable for 3-35kV indoor switchgears, including built-in switchgears, handcart switchgears, fixed switchgears and loop-net switchgears. It is also suitable for 0.4kV low-voltage switchgears such as fixed switchgears and drawer switchgears.

Product Selection


 

Specification

Wireless temperature sensor

ACREL Model

ATE100

ATE100M

ATE200

ATE400

Power supply

powered by battery

powered by CT sensing

Transmission frequency

470Mhz or 433Mhz

Sampling cycle

25s

15s

Transmission cycle

5min

15s

Measuring range

-50℃~125℃

Accuracy

±1℃

Communication distance

150m in open space

Operation Life

>5years(battery life)

>10years

Installation

Screw bolted

installation

Magnetic

installation

Belted

installation

fixed by

compound metal

Application

circuit breaker contact, busbar, cable contact and other big current

Transceiver

ACREL model

ATC450-C

ATC600

Power supply

DC24V

AC/DC 110V/220V

Installation

Din rail 35mm or screw fixed

Din rail 35mm

Communication

Modbus RTU RS485

Modbus RTU RS485

Extra function

No

Alarm output 2DO

 

Structure


 

Dimension


 

Typical Connection

111

 

Photos on site

PARAMETER

Item

Value

Wireless temperature measurement

Wireless frequency

470Mhz / 433Mhz

Communication distance

150m in open area

Sampling frequency

25s

Transmission frequency

4min

Power source

Battery

Installation

Bolted

Range of temperature

-40°C~125°C

Precision

±2 °C

Application

Joints between bus bar and cable

Service life

>5 years

Environmental requirement

Operating temperature

-40°C~125°C

Relative humidity

<95%

Atmospheric pressure

86kPa 〜106kPa

CONTACT US