Jiangsu Acrel Electrical Manufacturing Co., LTD.
tel:
+86 18761509710email:
besty.chen@email.acrel.cn● Closed Type Hall Current Sensor
● Rated current input: 0~(200-1000)A; Rated output: 4V / 5V
● Aperture: 40mm; Power supply: ±12V / ±15V
● AC, DC, pulse and other complex current
● Quick response, wide range of measurement, high precision, strong overload capcity, good linearity and excellent and anti-interference performace
General
Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signals are convertedaccording to the Hall Effect theory, the can be directly acquired by AD, DSP, PLC, secondary instruments and other devices.
Hall current sensors are widely applicable for acquisition and feedback control of current signals in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature the quick response, wide range of measurement, high precision, strong overload capcity, good linearity and excellent and anti-interference performace.
It is insulative between the primary and secondary grade of AHKC-E series current sensor which can be used for measuring direct current, alternating current and pulse current.

Dimension
Spec. and size (unit:mm)
|
Size Specification |
Outline size(mm) |
Through size(mm) |
Figure |
|
AHKC-E |
53*72*16 |
Φ20mm |
Fig.1 |
|
AHKC-EA |
53*72*16 |
Φ40mm |
Fig.1 |
|
AHKC-EB |
53*72*16 |
Φ60mm |
Fig.1 |
|
AHKC-LT |
90*73.5*25 |
Φ32.5mm |
Fig.2 |
|
AHKC-C |
/ |
31*13 |
Fig.3 |
|
AHKC-BS |
43*32.5*19 |
20.5*10.5 |
Fig.3 |
|
AHKC-BSA |
43*32.5*19 |
20.5*10.5 |
Fig.3 |
|
AHKC-F |
74*57*22 |
43*13 |
Fig.4 |
|
AHKC-FA |
94*60.5*26.5 |
52*15 |
Fig.4 |
|
AHKC-HAT |
94*76.5*24 |
52*32 |
Fig.4 |
|
AHBC-LTA |
68*57*20.5 |
Φ20mm |
Fig.2 |
|
AHBC-LT1005 |
119*112*40 |
Φ40mm |
Fig.2 |
|
AHBC-LF |
155*135*45 |
Φ60mm |
Fig.2 |
Wiring



7. The positive and negative poles of the power supply cannot be reversed.
Related Solution
|
Type |
Rated current |
Rated output |
Measuring Aperture |
Power Supply |
|
AHKC-E |
0-(200-500)A |
5V/4V |
Φ20mm |
±15V |
|
AHKC-EA |
0-(200-1000)A |
5V/4V |
Φ40mm |
±15V |
|
AHKC-EB |
0-(500-1500)A |
5V/4V |
Φ60mm |
±15V |
|
AHKC-LT |
0-(100-800)A |
5V/4V |
Φ32.5mm |
±15V |
|
AHKC-C |
0-(100-800)A |
5V/4V |
31*13 |
±15V |
|
AHKC-BS |
0-(50-500)A |
5V/4V |
20.5*10.5 |
±15V |
|
AHKC-BSA |
DC0-(50-500)A |
4-20mA |
20.5*10.5 |
12V/24V |
|
AHKC-F |
0-(200-1000)A |
5V/4V |
43*13 |
±15V |
|
AHKC-FA |
0-(200-1500)A |
5V/4V |
52*15 |
±15V |
|
AHKC-HAT |
0-(400-2000)A |
5V/4V |
52*32 |
±15V |
|
AHBC-LTA |
100A-300A |
50mA/100mA |
Φ20mm |
±15V |
|
AHBC-LT1005 |
1000A |
200mA |
/ |
±12V-±24V |
|
AHBC-LF |
2000A |
400mA |
/ |
±12V-±24V |