Panel DC Power Meter PZ72L-DE/C

Cut-out Size: 67*67mm

● LCD display; Panel Mounted
● RS485(MODBUS-RTU)
● Set parameters
● DI/DO, Relay alarm output

● Measure voltage, current, power, forward and reverse power in DC system
● Applications: DC panels, PV solar, telecommunications base stations, and charging posts, etc.

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
porduct detail

General

PZ series intelligent DC energy meter is designed for applications such as DC panels, solar power, telecommunications base stations, and charging posts. This series of devices can measure voltage, current, power, forward and reverse power in DC system. It can be used for local display, and connected with industrial control equipment, computers, form a measurement and control system.

It has a variety of external excuse functions for the user to choose: RS485 communication interface, Modbus-RTU protocol, relay alarm output, digital input/output. According to different requirements, through the instrument panel keys, you can set the ratio, communication parameters.

The product meets the relevant technical requirements of the standard DC power meter specification, Non-vehicle charging electric energy metering for electric vehicles, single-phase energy meter specification.

Dimension

微信截图_20201105165850
微信截图_20201105165902

Wiring

Wiring sample of current and voltage

Installation

1. Cut out a hole on the object on where we will intall the meter according to dimension of meter referred above.

2. Remove the buckle on the meter off.

3. Install the meter into the cut-out hole.

4. Buckle up and fixed the meter.

Typical Connection

PARAMETER

Input

DC voltage

Input range

Direct access: 0~100V, 0~500V, 0~1000V

Input resistance

≥6kΩ/V

DC current

Input range

Indirect access: 0-2500A

Shunt

75mV

Hall Current Sensor

0~5V

Power consumption

≤1mW

Overload

1.2 times (normal), 2 times/second (continued)

Accuracy

Class 0.5

Pulse constant

750V、300A; 1000V、300A;1000V、200A: Default pulse constant: 100imp/kWh

Function

Measuring

Voltage、Current、Power

Calculate

Current total electricity,Current positive energy,Current reverse power

DI、DO

PZ72: 2DO+2DI; PZ96: 2DO+4DI

Display

LCD (the backlight delay time can be adjusted) or LED

Communication

RS485, Modbus-RTU / DL/T645-07, Band: 1200/2400/4800/9600, Infrared: 1200

Working power

Voltage range

85~265VAC/DC、50/60Hz; 20~60VDC; 100~350VDC

Power consumption

≤2W

Insulation resistance

≥100MΩ

Power frequency withstand voltage

3kV/1min (RMS)

Environment

Temperature

Working temperature: -25℃~+60℃; Storage temperature: -20℃~+70℃

Humidity

≤ 93%RH (no condensation, no corrosive gases)

Altitude

≤ 2500m