Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Product Detail

General

AGF-M Perforation type PV confluence acquisition device is specially designed for smart PV combiner box. It is used for monitoring the running state of solar panels in solar cell arrays, measuring the currents of solar cell, detecting the state of surge protection devices and DC breaker. The device is equipped with RS485(Modbus) communication port for transmitting all the datas to master device.

Specification



Wiring



Dimension

Power supply module size(Figure 1)


8-channel confluence acquisition module installation dimension(Figure 2)


4-channel confluence acquisition module installation dimension(Figure 3)



LCD display module installation dimension (Figure 4)


Installation

Connections of modules (Figure 5)


Installation schematic


Application

parameter
Item AGF-M4T AGF-M8T AGF-M12T AGF-M16T AGF-M20T AGF-M24T
Input channels 4 8 12 16 20 24
Rated current DC 0~20A
Response time 1s
Accuracy 0.5 class
Temperature
coefficient
400ppm
RS485
communication
RS485/ModBus-RTU protocol,4800/9600/19200/38400bp
Additional function
Switch input 3-way input(optocoupler or dry contact mode)
General technical parameters
Temperature/
Humidity

Working temperature: -35~+65℃, humidity95%, no condensation,

no corrosion gas place*Display module, work temperature:-20~+70℃

Temperature
measurement
function
To measure the inner temperature of box (-20℃~100℃)
Altitude ≤3000m
Insulation
resistance
≥100MΩ
Industrial
frequency
withstand
voltage
power/communication/switching input/cell voltage input--AC 2kV/1min
(When the auxiliary power supply is DC1500V, the withstand voltage between the
power supply, photocell input and other circuit is AC 2.7kV)
Current input/power、cell voltage 、communication、switching
state—AC3.5kV/1min
EMC
GB_T 17626.2-2006;
Electrostatic discharge immunity test 3rd grade, air discharge 8kV, contact
discharge 6kV.
GB_T 17626.4-2008;
Electrical fast transient immunity test grade 4, common mode 4kV, difference
mode 2kV
GB_T 17626.5-2008;
Surge(shock) immunity test grade 4, common mode 4kV, difference mode 2kV
GB_T 17626.8-2006;
Power frequency magnetic field immunity test grade 4