AKH-0.66/I 30I Measurement CT

● Model: AKH-0.66/I 30I Low Voltage Solid Core CT

Busbar Type/QTY: 30*10mm/1pcs

Aperture: 22mm; Ratio: 15~600/5(1)A

● Current transformer for AC measurement

● Suitable for cables or copper bus; Used with energy meters or relays

● 30I, 40I Optional Din Rail Mounted

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
product detail

General

They are patented and flip designed. The appearance is nice and the wiring is convenient. The transparent polycarbonate material is selected for the flip.We can clearly see the secondary lead wiring. It have square-round hole for both cable and bus passing through.

As alternating current signal acquisition element,it is generally matched with measuring instruments and widely used in electrical sets.


Specification

* Model: AKH-0.66 30I

* Rated secondary current: 1A or 5A

* Rated primary current: 15~600A

* Rated voltage: 660V AC

* Test voltage: 3kV AC(1min)

* Rated frequency: 50/60Hz

* Security factor: FS<5

* Continuous overload: 120%In

* Protection level: IP30

* Operating temperature: -25℃~+50℃

* Storage temperature: -40℃~+80℃

* Relative humidity: ≤90%RH, no condensation

 

Dimension

Spec. and size (unit:mm)

Type

Outline size

Through size

Mounting size

Size

W

H

D

a

e

Φ

M

N

30 I

60

78

36

31

11

23

34

57.5

40 I

75

95

45

42

11

31

40

57.5

60 I

102

130

45

61.5

21

45

42

57.5

80 I

118

140

45

82

11

52

60

57.5

Specification

Wiring


 

Installation

Fixed by Sheet Metal (Figure 1)

Fixed by Clutch Cover (with curved Support Plate) (Figure 2)

 


Fixed by Clutch Cover (with curved Support Plate) (Figure 3)

 

Fixed Installed on 35mm Standard DIN Rail (Figure 4)

Photo on Site


parameter
Specification
Rated Current Ratio(A)
Precision Degree and Corresponding Rated Load (VA)
Straight-Through Tums
Bus Spec(mm)/Number

Max. Cable Outer Diameter (mm)

Installation
0.2
0.5
1
30I
15/5(1)
1.5
5
/
Ф22
A
20/5(1)
1.5
4
25-30/5(1)
1.5
3
40-60/5(1)
1.5
2
75-100/5(1)
1.5
1
30×10/1
A、B
150-200/5(1)
2.5
1
250/5(1)
3.75
1
300-450/5(1)
5
1
500/5(1)
10
1
600/5
10
1
40I
10/5(1)
1.5
10
/
Ф30
A
15/5(1)
1.5
8
20/5(1)
1.5
5
25-30/5(1)
1.5
4
40/5(1)
1.5
3
50-75/5(1)
1.5
2
100/5(1)
1.5
1
40×10/1
A、C
150/5(1)
2.5
1
200/5(1)
2.5
1
250/5(1)
3.75
1
300-450/5(1)
5
1
500-800/5(1)
10
1
1000/5(1)
10
1
60I
150/5(1)
2.5
1
60×10/1
60×6/1-2
Ф44
A、C
200-250/5(1)
2.5
1
300-450/5(1)
5
1
500-800/5(1)
10
1
1000-1250/5(1)
10
1
1500-2000/5(1)
20
1
2500/5(1)
30
1
80I
150/5(1)
2.5
1
80×10/1
Ф50
A、C
200-250/5(1)
2.5
1
300-400/5(1)
5
1
500-800/5(1)
10
1
1000-1250/5(1)
10
1
1500-2000/5(1)
20
1
2500-3000/5(1)
30
1

CONTACT US