Digital Multifunction Power Meter 0.5S APM800

● True RMS Measurements

● Unbalance & Phase Angles

● Demands and Multi-Tariff energy

● Max/Min Log with Timestamp

● Alarms and SOE Logs

● External Option module

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
FAQ

Q: What’s the storage capacity, storage format and data storage interval of SD card?

A: The meter is equiped with standard 4G SD card while saving the data of electricalparameter, energy, event, SOE, alarm. Also, the setting of storage interval could bechanged. (1 min interval for electrical parameter and 1 hour interval for energy)

Q: How should I select the expanded modules of APM8xx?

A: Our users can select 3 of the optional modules at will even repeatly except forcommunication module. Also, the order of module installation could be random.

Q: The features of APM8xx?

A: Except for wave record and SD card storage function, 0.2S measuring accuracycan also be a option. Besides, APM8xx can serve as reverse display meter (whichmeans 3-phase electrical parameters measuring plus 8-channel reverse display)Also, users can measure the data through browser by using Ethernet auto WEB.

Q: As for the auxiliary power supply of APM8xx?

A: AC/DC 85~265V or 115~415V is both optional. Also, 380V line voltage can alsoserve as power supply.

parameter
Connection
3 phase 3 wire, 3 phase 4 wire
Frequency
50Hz
Input Voltage
Rated Voltage
AC 100V, 110V, 400V, 690V
Overload
1.2 times rated value(continuous); 2 times rated value(1 second)
Consumption
<0.5VA(per channel)
Input Current
Rated Voltage
AC 1A, 5A
Overload
1.2 times rated value(continuous); 2 times rated value(1 second)
Consumption
<0.5VA(per channel)
Accuracy
Voltage, current and power
Class 0.5S(APM800, APM810)

Class 0.2S(APM801, APM830)

Active power
Reactive power
Class 2
Harmonic
1%(2-42nd), 2%(43-63rd)
Switch inputs
Passive contact inputs, built-in power supply
Relay outputs
Contact type: open contact in main part, changeover contact in module
Pulse capacity: 3A/AC250V, 3A/DC30V
Pulse output of energy
Output mode: Optocoupler pulse with open collector
Pulse constant: 4000(5A), 8000(1A) imp/kWh
Analog output
DC0-20mA, 4-20mA, 0-5V, 1-5V output, accuracy class 0.5%,
Load resistance≤500Ω
Analog input
DC0-20mA, 4-20mA, 0-5V, 1-5V input, accuracy class 0.5%,
Storage card
Standard capacity: 4G, TF card up to 32G capacity
Communication
RS485(Modbus-RTU), Profibus(Profibus-DP),
Ethernet(Modbus-TCP, HTTP, DHCP)
Auxiliary power supply
AC/DC 85~265V or AC/DC 115~415V
Electromagnetic compatibility
IEC 61000 standard(Level 4)
Environment
Operating temperature
-20~65℃
Storing temperature
-20~70℃
Humidity
≤95%(No condensation)
Altitude
≤2500m

FAQ

Q: What’s the storage capacity, storage format and data storage interval of SD card?

A: The meter is equiped with standard 4G SD card while saving the data of electricalparameter, energy, event, SOE, alarm. Also, the setting of storage interval could bechanged. (1 min interval for electrical parameter and 1 hour interval for energy)

Q: How should I select the expanded modules of APM8xx?

A: Our users can select 3 of the optional modules at will even repeatly except forcommunication module. Also, the order of module installation could be random.

Q: The features of APM8xx?

A: Except for wave record and SD card storage function, 0.2S measuring accuracycan also be a option. Besides, APM8xx can serve as reverse display meter (whichmeans 3-phase electrical parameters measuring plus 8-channel reverse display)Also, users can measure the data through browser by using Ethernet auto WEB.

Q: As for the auxiliary power supply of APM8xx?

A: AC/DC 85~265V or 115~415V is both optional. Also, 380V line voltage can alsoserve as power supply.

CONTACT US