● Type: PZ96L-E4/KC

● Cut-out Size: 88*88mm

● Rated Current: 1A, 5A (CT Connection)

● Rated Voltage: AC 220V, AC380V, AC660V

● RS485 MODBUS-RTU Communication

● LCD display; Panel Mounted

● Class 0.5

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
product detail

General

PZ Series electric energy meters, adopting AC sampling technology, can measure many three phase grid electrical parameters such as current, voltage, power, electric energy etc. directly or indirectly. It may be used for local display, and connected with the control equipment to form measuring and controlling system.

Fitted with RS-485 communication port, adopting compatible Modbus-RTU protocol, meters can switch electric parameter signal into standard analog output, with four-channel (two-channel) switching input / two-channel switching output. Based on different requirements, by keys on the faceplate, electric parameters for transformation ratio, alarm, communication etc. can be set up and controlled.

PZ series meters have extra high price performance ratio, can simply replace traditional electric transducer and measuring meters As an advanced intelligent, digital front end acquisition component, this electric meters have widely used in various control system, SCADA system and energy source management system.

Specification

Model
The Basic Function
Outline Dimension
Optional Function
PZ96L-E3
(3p3w)

Measurement of active electric energy (EPI/EPE),

reactive electric energy (EQL/EQC),

active power, reactive power, power factor,

three-phase voltage, three-phase current and frequency

96*96mm
1.One channel RS485 communication (/C)
2.One channel Profibus-DP (/CP)
3.RS485+4DI2DO (/KC)
4.Profibus-DP+4DI2DO(/KCP)
5.Up to two channel Analog output(/M or /M2)
6.Analog output+RS485 (/MC or /M2C)
7.Analog output+Profibus-DP (/MCP or /M2CP)
PZ96L-E4
(3p4w)

 

Dimension

Wiring

Wiring sample of current and voltage

Typical Connection

Related Solution

Electric Energy Management System

parameter
Technical Parameter Indexes
Network Three-phase three-wire、three-phase four-wire
Voltage Measuring range 10~230V phase voltage
15~400V line voltage
Overload Instantaneous 2 times/1s
Current Measuring range 5A input, primary current 0~9999A;
Overload Continue 1.2 times, instantaneous 10 times/1s
Frequency 45Hz~65Hz
Auxiliary
power supply
AC 85V~265V
DC 100V~350V
Accuracy Current, voltage Class 0.5
Power, energy Class 1
Power dissipation <5VA
Switch input Dry contact input, built-in power supply
Relay output 3A 250VAC/3A 30VDC
Environment Operating temperature -10℃~55℃
Storage temperature -20℃~70℃
Relative humidity ≤93%( without condensation)
Altitude ≤2500m
Electromagnetic compatibility Electrical Fast Transients 4kV 5kHz
Electrostatic discharge Contact 6kV/air 8kV
Radiofrequency electromagnetic field
10V/m
Communication RS485