Multi Channel Lora Energy Meter ADW220

● Rated Current: AC5A, 100A

● Rated Voltage: 3x220V/380V AC (3P4W)

● Measure up to 4 circuit 3 phase

● Measure all electric parameters

● RS485 interface Modbus-RTU communication

● 35mm DIN Rail Installation

● Lora (470/433MHz) wireless communication
● Split core open loop CTs, 5A / 100A/ 400A / 600A
● External function module, such as MK(switching inputs and outputs), MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
product detail

General

ADW220 series multi-loop power meter is mainly used for the measurement of all electric parameters of three-phase circuit. Colleagues can select the current input of the maximum four circuits. ADW2XX series products are connected by split core current transformer, easy to install on site, and realize remote wireless communication through wireless communication module. It has LCD display and Lora wireless capability.

1

Specification

ADW200

Front Panel

Optional Module

 

External Module (MTL): 12 External NTC Temp. Measurement; 4 Channels Residual Current Measurement

External Wireless Module(AWT100): Downlink RS485; Uplink 4G, 2G, NB, Lora, LoraWAN, Ethernet, WiFi, GPS, Profibus
External Module(MK): 12 Channels DI + 4 Channels DO

Typical Connection

Dimension

微信截图_20210304162844

Current Transformer

Matched with ADW2xx Series

Dimension(mm) Perforation size (mm)
W H D M N φ1 φ2
AKH-0.66/K-φ 10N 27 44 32 25 36 10 9
AKH-0.66/K-φ 16N 31 50 36 27 42 16 17
AKH-0.66/K-φ 24N 39 71 46 36 52 24 23.5
AKH-0.66/K-φ 36N 42.5 82 58 40 56 36 35

Picture of Current Transformer

Installation

Wiring

PARAMETER

Specification

3 phase 3 wires, 3 phase 4 wires

Voltage

Rated voltage

3×220/380V

Consumption

<0.5VA(Single phase)

Impedance

>2MΩ

Accuracy class

±0.2%

Current

Input current

5A

Consumption

<0.5VA(A phase)

Accuracy class

±0.2%

Power

Active, reactive, apparent power, ±0.5℅

Frequency

45~65Hz, ±0.2%

Temperature

-40℃~99℃

Energy

Active energy(Accuracy : class 1), reactive energy(Accuracy:class 2)

Clock

≤0.5s/d

Communication

RS485, Modbus RTU

Relative temperature

-25℃~+55℃

Relative humidity

≤95℅(No condensation)

Auxiliary power supply

<10VA

Switching

input

dry contact input; built-in power supply

output

Output mode :relay normally open contact output
Contact rating: AC 250V/3A  DC

CONTACT US