Rail Mounted IoT Wireless Energy Meter ADW210

● Rated Current: AC5A, 100A

● Rated Voltage: 3x220V/380V AC (3P4W)

● Measure up to 4 circuit 3 phase

● Measure all electric parameters

● RS485 interface Modbus-RTU communication

● LCD Display; 35mm DIN Rail Installation
● Split core open loop CTs, 5A / 100A/ 400A / 600A
● External function module, such as MK(switching inputs and outputs), MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
product detail

General

ADW210 series rail type multi-loop power meters are mainly used for measuring the full electric parameters of multiple three-phase circuits, up to four three-phase loop current inputs can be connected simultaneously. It can measure voltage and current, power, power factor, phase angle, unbalance, harmonic and other parameters.

1

Specification

ADW200

Front Panel

Optional Module

 

External Module (MTL): 12 External NTC Temp. Measurement; 4 Channels Residual Current Measurement

External Wireless Module(AWT100): Downlink RS485; Uplink 4G, 2G, NB, Lora, LoraWAN, Ethernet, WiFi, GPS, Profibus
External Module(MK): 12 Channels DI + 4 Channels DO

Typical Connection

Dimension

微信截图_20210304162844

Current Transformer

Matched with ADW2xx Series

Dimension(mm) Perforation size (mm)
W H D M N φ1 φ2
AKH-0.66/K-φ 10N 27 44 32 25 36 10 9
AKH-0.66/K-φ 16N 31 50 36 27 42 16 17
AKH-0.66/K-φ 24N 39 71 46 36 52 24 23.5
AKH-0.66/K-φ 36N 42.5 82 58 40 56 36 35

Picture of Current Transformer

Installation

Wiring

PARAMETER

Specification

3 phase 3 wires, 3 phase 4 wires

Voltage

Rated voltage

3×220/380V

Consumption

<0.5VA(Single phase)

Impedance

>2MΩ

Accuracy class

±0.2%

Current

Input current

5A

Consumption

<0.5VA(A phase)

Accuracy class

±0.2%

Power

Active, reactive, apparent power, ±0.5℅

Frequency

45~65Hz, ±0.2%

Temperature

-40℃~99℃

Energy

Active energy(Accuracy : class 1), reactive energy(Accuracy:class 2)

Clock

≤0.5s/d

Communication

RS485, Modbus RTU

Relative temperature

-25℃~+55℃

Relative humidity

≤95℅(No condensation)

Auxiliary power supply

<10VA

Switching

input

dry contact input; built-in power supply

output

Output mode :relay normally open contact output
Contact rating: AC 250V/3A  DC