Single Phase Din Rail Energy Meter ADL10-E

● Rated Current: 10(60)A

● Rated Voltage: AC 220V

● RS485 MODBUS-RTU Communication

● LCD display; 35mm DIN Rail Installation

● Diverse Electricity Parameters Measurement
● kWh Class 1, Kvarh Class 2
● U、I、P、Q、S、PF、kWh、kvarh

● Small Compact Size

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
product detail

General

ADL10 single phase din rail electric kWh energy meter is designed for single phase active energy measurementon low voltage system, in the same time it can measure the electrical parameters like voltage, current, power and so on. There is also RS485 communication can be chosen.

LCD display and electricity pulse output function is installed in the power meter; clock, rate period parameters can be set also. Data swap with the super ordination machine via RS485 communication interface greatly facilitate the power automated administration.

This power meter has advantages of smaller volume, high precision, good EMC, easily installing etc. All meters meet the related technical requirements of electronic power meter in the IEC62053-21、IEC62053-22 standards.

Product Selection

initpintu_副本1111

Specification

Technical Parameter

ADL10-E

ADL100-ET

ADL100-ET/CT

ADL200

Accuracy class

Class 1

Rated voltage

220V

Current specification

10(60)A

20(100)A

10(80)A

Reference frequency

50Hz

Starting Current

Direct Connecting

0.004lb

Power Consumption

Voltage line

<10VA

Current line

<4VA

Electricity pulse output

80ms±20ms

Clock error

≤0.5s/D

Temperature range

Normal working temperature:-25~55℃

storage temperature:-40~70℃

Relative humidity

≤95%(No condensation)

Outline (L*W*H)

18*88*70mm

36*88*70mm

Installation method

TS35mm guide rail

Communication

RS485 Modbus-RTU

RS485 Modbus-RTU, Infrared

RS485 Modbus-RTU

Dimension

Wiring

Wiring sample of current and voltage

Typical Connection

Related Solution

Electric Energy Management System

PARAMETER

Technical Parameter

ADL10-E

ADL100-ET

ADL100-ET/CT

ADL200

Accuracy class

Class 1

Rated voltage

220V

Current specification

10(60)A

20(100)A

10(80)A

Reference frequency

50Hz

Starting current

Direct connecting

0.004lb

Power consumption

Voltage line

<10VA

Current line

<4VA

Electricity pulse output

80ms±20ms

Clock error

≤0.5s/D

Temperature range

Normal working temperature:-25~55℃

storage temperature:-40~70℃

Relative humidity

≤95%(No condensation)

Outline (L*W*H)

18*88*70

36*88*70

Installation method

TS35mm guide rail

Communication

RS485 Modbus-RTU

RS485 Modbus-RTU, Infrared

RS485 Modbus-RTU

CONTACT US