AID120 Remote Alarm Indicator

● Remote monitoring
● LED indicators: On, Insulation, Overload, Overtemp
● Mute button
● Test button
● Auxiliary power supply: DC24V
● RS485(MODBUS-RTU)
description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
product detail

General

AID120 is usually combined with AIM-M100, AID120 is usually used in combination with AIM-M 100 for data exchange through RS485 communication. It is fit for embedding into operating room or nurse station internal wall installation which can monitor one set of AIM-M100 insulation monitoring device with the function of sound-light alarm on failures like insulation, overload, over temperature and equipment failure etc. and digital display and RS485communication.

 

Function

The insulation resistance alarm value, load current alarm value and transformer temperature alarm value of each system insulation monitoring instrument can be set up remotely.
When there are insulation faults, overload, excessive temperature rise of the voltage transfomer or wiring faults in any of the monitored system, centralized alarm and display instrument can provide corresponding sound and light alarm function, and can manually eliminate the alam sound.

Display

Dimension

  • Front view
  • Side view
  • Hole size

Terminal Description

NOTE: The 24V power supply can be connected by multiple copper wires of 2x1.5mm², and the RS485 communication terminal can be connected by shielded twisted pair of 2x1.5mm².

Installation

Typical Connection

Structure


Common problems

For common problems, the causes can be determined and the faults can be eliminated according to the phenomenon of each instrument and the fault types:

Fault phenomenon

Possible causes and troubleshooting

The instrument is not lit.

The 24V power supply is not connected well. Check the wirings of 24V and G terminals and rewire.

Communication indicator does not flash

In the system, the AIM-M100 monitor communication line is not connected properly. Check the communication line and confirm whether the matching resistance is connected properly.

Note: If the above faults occur, interrupt the power to troubleshoot, and adjust the wirings until everything is normal.
PARAMETER

AUX POWER

Voltage

DC 24V

Power consumption

0.6W

Insulation measure range

10~999kΩ

Insulation alarm range

50~999kΩ

Transformer Load Rate

Percentage display

Current alarm range

14A18A22A28A35A45A

Temperature alarm range

0~+200

Alarm mode

Audible and visual alarm

Alarm type

Insulation fault, overload, overtemperature, device failure

Communication mode

RS485MODBUS-RTU

Display mode

LED display